I built a home about 7 years ago that is having all kinds of problems with the tile flooring cracked tile displaced grout creaky flooring 1 2 deflection in some areas.
Minnesota building code sub layer for tile flooring.
The tile council of america tca recommends a max.
Definition of naics code 238330.
Introduced around 1970 cement based backer board and thin set adhesives not only made professional installation quicker and therefore cheaper but it also made it possible for everyday diyers to install high quality ceramic.
Floor cantilever spans shall not exceed the nominal depth of the wood floor joist.
Perimeter tiles shall be fastened with a minimum of one fastener per tile.
Significant changes in the 2020 minnesota residential code.
The term tile means burned clay products as used in the tile industry either glazed or unglazed and to all composition materials made in single units up to 15 x 20 x 2 except quarry tiles larger than 9 x 9 x 1 1 4 also to mixtures in tile form of cement plastics and metals that are made for and intended for use as a finished.
Clay and concrete roof tiles shall be fastened in accordance with this section and the manufacturer s installation instructions.
Although it is not enforceable by municipalities unless it is adopted by local ordinance it creates a level playing field for the construction industry by establishing the minnesota state building code as the standard for the.
The minnesota state building code is the minimum construction standard throughout all of minnesota.
While building codes limit deflection in living spaces to l 360 under uniform loads code compliant floors may still have too much flexing between joists under point loads.
The 2020 minnesota state building code is effective march 31 2020 except for the minnesota mechanical fuel gas code which is effective april 6 2020.
Floor cantilevers constructed in accordance with table r502 3 3 1 shall be permitted when supporting a light frame bearing wall and roof only.
Excessive deflection in a wood floor system is a common cause for cracking in thin set tile installations.
It is the minimum construction standard throughout all of minnesota.
The builder hired used 3 4 osb for the flooring while the tile contractor used a 1 4 cbu under the tile thus achieving 1 in total depth.
Deflection of l 360 for ceramic tile and l 720 for natural stone tiles.
Floor cantilevers supporting an exterior balcony are permitted to be constructed in accordance with table r502 3 3 2.
Subflooring requirements for tile floors.
View information about the 2020 minnesota state building codes.
Previously ceramic tile floors were generally installed on a wet mortar base layer laid by a skilled professional.
View the 2015 minnesota state building codes.
Naics code 238330 flooring contractors.
Residential floors are typically sized for a live load of 40 psf and a dead load or 10 psf.